B Braun Infusomat Space User Manual

Class 1 Recall Expansion: B. Braun Infusomat Space Infusion System. This is an expansion of a previous recall, initiated by B. Braun in January, 2012, due to the potential for breakage of the anti free flow clip catch located inside the infusion pump door. Breakage may occur when the IV set anti free flow clip catch. The Perfusor ® Space 2nd Generation Syringe Pump is the first syringe pump to include air and road transport in the 510(k) cleared indications for use. It is intended for use on adults, pediatrics, and neonates for the intermittent or continuous delivery of parenteral fluids, enteral fluids, medications, blood and blood products through clinically accepted routes of administration. A TheSpaceSystemshouldnotbeexposedtoexcessivemagneticfields(e.g.inan MRIroom).Ifnecessary,longerinfusionlinescanbeused.Whenusinga defibrillator. View and Download Braun Infusomat Space service manual online. Infusion Pump. Infusomat Space Medical Equipment pdf manual download. Also See for Braun Infusomat Space. Braun Infusomat. Medical Equipment Braun Stimuplex HNS 11 User Manual. Nerve stimulator for regional anaesthesia, neurology (28 pages).

  1. B Braun Infusomat Pump
  2. B Braun Pump User Manual
  3. Infusomat Space Line
  4. B Braun Infusomat Space P User Manual
  5. B Braun Infusomat Space Battery Specifications

B Braun Infusomat Pump

One moment please...

Operation. The initial training of the Infusomat® Space is to be performed by B. Braun sales personnel or other authorized persons. After each software update, the user is required to inform himself about the changes to the device and accessories in the instructions for use. 0 Important Information on this Manual 0- 6 Infusomat P 2.0gb ISO 9000 ff/EN 46 000 ff B. Braun is certified in accordance with DIN ISO 9001 and DIN EN 46 001. This certification also includes maintenance and service. The Infusomat P complies with the IEC/EN60601-1 and IEC/EN60601-2-24 standards and is certified with the CE label ac.

  • Parts
  • Videos
  • News
DESCRIPTION
A small, stackable infusion pump system for most care areas and easy transport

B Braun Pump User Manual

Designed with both adult and pediatric facilities in mind, the small 9' x 6' Infusomat® Space pump weighs only 3 pounds and easily fits into a range of environments. The lightweight large volume pump allows for flexibility and easy transport within a number of care settings.
The system is designed for higher acuity care facilities, offering a large drug library as well as the capability to build up to 24 pumps in a single bedside tower.

B braun infusomat space user manual 2017
FORUMSView All (19)
Ask a New Question

1

Reply
-GSM
a month ago
a month agoService Training & Hi-Base Software
Please could someone advise me who the US contact is at BBraun to arrange service training and access to the BBraun Hi-Base Software?Reply
- Afternoonmeds
6 months ago
6 months agoSoftware
We got some used B Braun Infusomat IV Infusion Pumps that0019s software shows the hospital we purchase them from. Is there a way to change this or do the pumps have to go back to B Braun.Reply

0

Replies
-jason@elitebiomedical
7 months ago
7 months agoCalibration Software
Looking to purchase the Infusomat Space Calibration Software and Interface Cable. Thanks in advance.Reply

Infusomat Space Line

DOCUMENTS / MANUALSView All


FEATURES

  • Small compact footprint
  • Strong lightweight pole clamp holds up to three pumps mounted horizontally or vertically
  • Easy-to-learn, easy-to-use intuitive user interface
  • Alarms are audible, clearly visible and differentiated using different tones
  • 1,500-entry drug library available

B Braun Infusomat Space P User Manual

SPECIFICATIONS

Flow Accuracy5 %
Flow Rate Range0.01 to 1200 ml/h
Infusion Pump TypeGeneral-Purpose
Height4.9 in
Length 2.7 in
Weight3 lbs
Width8.4 in
User
FDA AlertsView All
Class 1 Recall Expansion: B. Braun Infusomat Space Infusion System

B Braun Infusomat Space Battery Specifications

This is an expansion of a previous recall, initiated by B. Braun in January, 2012, due to the potential for breakage of the anti free flow clip catch located inside the infusion pump door. Breakage may occur when the IV set anti free flow clip catch