Nova Biomedical Lactate Plus User Manual

BioProfile® FLEX2

The combination of reduced sample volume, fast analysis time and maintenance-free makes BioProfile® FLEX2 the first choice in regard to sample analysis from microbioreactor systems.

The full 16 cell culture test menu includes Glucose, Lactate, Glutamine, Glutamate, Ammonium, Sodium, Potassium, ionized Calcium, pH, pCO2, pO2, total cell density, viable cell density, viability, cell diameter and osmolality.

Maintenance-free Mircosensor Cards

Utilizing Nova’s maintenance-free MicroSensor Card technology eliminates any electrode maintenance work. All biosensors are combined in the credit card sized MicroSensor Card, which are replaceable within a few seconds.

Reduced sample volume and fast analysis time

A complete test profile with all 16 parameters takes 4 minutes and requires only 265 µL of sample. Individual test profiles (such as pH, Gas/Chemistry) require only 120 µL sample and complete in 2 minutes analysis time. Compared to the previous model, with FLEX2 the required sample volume was reduced by 75% and at the same time test results are available 2 minutes quicker.

Stat Profile ® Prime ® Plus A technology evolution in critical care testing. Stat Profile Prime ® Plus is a modern blood gas analyzer. It analyses blood gases, electrolytes, metabolites, CO-Oximetry and 32 calculated results from a small whole blood sample. Automated onboard quality controls save hours of labor each week compared to manual control testing, using several levels of control ampules. The liquid quality controls of the FLEX2 are provided in closed, chip-coded cartridges, which can be used up to 30 days and run automatically at user-selected intervals. Automated, 96-well plate analysis. Nova Biomedical recommends that the user of this device read this manual and accompanying product inserts com-pletely before performing blood measurements. Intended Use The Lactate Plus Meter System is intended for use by healthcare professionals to quantitatively measure lactate in whole blood to evaluate physical performance and/or to. Oct 22, 2013  CAUTION: Do Not attempt to open the Lactate Plus Meter to make any repairs. Your warranty and all claims will be void! Only Nova Biomedical.

Lactate Plus is a compact meter that measures whole blood lactate in 13 seconds from a tiny blood drop. Lactate Plus provides fast and accurate results, and offers virtually painless testing. Nova Biomedical is the world technology leader in the development of fast, whole blood analyzers to support the care of hospitalized and critically. Product Documentation. SDS Document Request. QC Insert Sheets. Lactate Plus measures blood lactate (muscle performance indicator) very quickly on a very small drop of blood. This results in a virtually painless, yet fast and accurate, test for lactate. Precaution: The Lactate Plus System is not FDA cleared for performing lactate measurements on persons for medical intervention. It is intended for sports.

Onboard automated quality control

Automated onboard quality controls save hours of labor each week compared to manual control testing, using several levels of control ampules. The liquid quality controls of the FLEX2 are provided in closed, chip-coded cartridges, which can be used up to 30 days and run automatically at user-selected intervals.

Automated, 96-well plate analysis

In addition to sampling from syringes and its load-and-go tray, FLEX2 is the only cell culture chemistry analyzer to offer automated sampling from 96-well plates. Plate configurations with mixed test panels may be saved for efficient loading of future plates with the same configuration.

Ideal for GMP Areas

Lactate Plus

The user-friendly software is fully compliant with 21 CFR Part 11. The persistence of this conformity is being maintained by the manufacturer through the usage of state-of-the-art technology and by providing continuous updates. This makes the FLEX2 the ideal analyzing system for GMP areas.

BioProfile FLEX2 Systemintegration

Lactate Plus Meter

BioProfile FLEX2 enables automatic sampling for every size of bioreactor. An integration is possible from 14 mL microscale reactor to the tallest SIP/CIP production units, including data management and automatic feedback control of every measured parameter. Unlike to other integrated analysers can the FLEX2 still be used for manual measurement as well as sample tray analysis, despite being integrated.

The combination of FLEX2 and ambr® 15 microscale bioreactor offers a range of unique advantages:

  • fully automated sampling and data management
  • automatic feeds, pH adjustment and other prozess optimization
  • Walkaway-automation with 24 vessel systems for up to 10 days
  • complete elimination of weekend shifts
  • saves app. 8 working hours for manual sampling per day
  • Up to 8 sampling sequences possible per vessel
  • analyses all key parameters out of only 400 µl sample

Nova Biomedical Lactate Plus Manual

Stat Profile® Prime®

Stat Profile Prime Technology Delivers Exceptional Performance

Stat Profile Prime combines the revolutionary microelectronics of the consumer world with Nova Biomedical’s innovative MicroSensor Card™ technology for a smaller, faster, more powerful and simpler analyzer.

Prime ABG
pH, pCO2, pO2
Prime CCS
pH, pCO2, pO2, Hct, Sodium Potassium, Chloride, Calcium
Prime CCS Comp

pH, pCO2, pO2, Hct, Sodium Potassium, Chloride, Calcium, Glucose, Lactate

Microsensor Card Technology

MicroSensor cards can be replaced, warmed, and calibrated in less than half the time of other cartridge systems, which take more than an hour to calibrate and can remain unstable with drift, frequent re-calibrations, and reduced throughput for even longer periods of time.

MicroSensor cards have flexible configurations:

• 200 Samples
• 400 Samples

Each cartridge is ready to use and easily replaced in seconds. Cartridge RFID technology automatically captures cartridge installation time, date, lot number, test parameters, and usage. There is significant savings in analyzer uptime when replacing only a calibrator cartridge, which has no warm-up time, compared to a two- to-four-hour wait for a combined cartridge systems.

Nova Biomedical Lactate Plus

Easy

Nova Biomedical Lactate Test Strips

A unique safety sample port protects the user from accidental contact with the sample probe and is easily accessed for all sample containers. The touchscreen is easily operated through the use of simple and intuitive prompts and requires minimal training.

Three simple steps to initiate a full 10-test profile

Nova

1. Press “Start”
2. Scan or enter patient ID
3. Press “Aspirate”

An optional integrated 1D/2D barcode scanner, conveniently located within the sample port, eliminates external handheld scanners and allows fast, error-free entry of operator and patient IDs.